Solid Sample Evaluation from
New Mexico well
-
Solubility test was utilized to evaluate Multi-StimScale's ability in addressing an acid insoluble scale sample collected from New Mexico well. A successful product will break, disperse, and solubilize the solids into fine pieces.​
-
Testing temperature was downhole temperature 95°F.​
-
Solubility test was conducted utilizing neat product.

Testing Summary
-
Customer provided solid sample collected from a recent pull. ​
-
Sample composition is mainly inorganic, based on initial observation. ​
-
Sample analytical evaluation was conducted to determine exact composition.​
-
Test was performed using 3 grams of the original sample and 100ml of the treatment.​
-
Samples were placed into a bottle with the treatment at room temperature and then in a water bath at 95°F for 24 hours.​
-
Observations were recorded during this time.
15% HCl Testing
Confirming it was not an acid soluble scale

Acid Solubilization Testing


Solid Analysis- NM well
Test Procedure
-
The procedure utilized in the barium solubility testing is as follows:
-
100mL of treatment is added to a prescription bottle.
-
~3 grams of solid sample was used and placed into bottle.
-
A hot water bath was set to testing temperature 95°F.
-
Samples were dosed at the prescribed treatment.
-
Bottles with treatment were placed in the hot water bath at testing temperature.
-
Samples were removed from the water bath after 24hours.
-
After cooling, sample was observed/ evaluated and final notes are recorded.
-
Additional bottles were evaluated with a dilution of the treatment with fresh water (FW) and same soaking conditions to evaluate performance vs neat product solubility.
Multi-StimScale results
Provided Solid Sample with Multi-StimScale at room temperature
Treatment with
Neat Product
Time: 24 hours
Test Set-up-Treatment and Sample Preparation 75/25 with Fresh Water
Time: 24 hours
Test Set-up-Treatment and Sample Preparation 50/50 with Fresh Water
Time: 24 hours
The evaluation of the solid sample collected from the downhole location confirmed that Multi-StimScale effectively solubilized and dispersed the primarily BaSOâ‚„-based scale, into fine particles without significant adhesion to the glass. Unlike traditional mechanical removal methods, which can be costly, time-consuming, and potentially damaging to well infrastructure, the Multi-StimScale approach provides several advantages:
​
Higher Efficiency: The treatment dissolves and disperses the scale chemically, significantly reducing the need for repeated mechanical interventions.
​
Improved System Integrity: Eliminates the risk of physical damage to well components associated with mechanical scraping or jetting.
​
Operational Simplicity: Simplifies scale removal by minimizing the need for complex downhole equipment and reducing the potential for equipment wear.
​
Cost Reduction: Potentially reduces overall well maintenance costs by extending the intervals between interventions and minimizing downtime.
​
Enhanced Water Quality: The product effectively addresses scale without impacting water quality or creating emulsions, crucial for maintaining optimal production flow.
​
Neat Multi-StimScale and the 75/25 treatment mixture with fresh water were identified as the most effective formulations. To enhance performance further, it is recommended to preflush with 2-5% MultiClean-2000 in fresh water to remove any organic coating, ensuring maximum contact and solubility.